Version 7 (modified by 9 years ago) (diff) | ,
---|
- Power Module (model CP3000AC54TEZ)
- Power Shelf (we have a J2014003L001)
Log
2016-09-12 Dan
config file updates for sane fan trays
/etc/rc.comtel
#CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned) CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned)
/etc/shelfman.conf.comtel
#MIN_FAN_LEVEL = 40 MIN_FAN_LEVEL = 1
/etc/shelfman.conf
# COOLING_FAN_DECREASE_TIMEOUT = 0 COOLING_FAN_DECREASE_TIMEOUT = 1 # COOLING_FAN_INCREASE_TIMEOUT = 0 COOLING_FAN_INCREASE_TIMEOUT = 1
2016-09-12
- Using a POT, the power shelf output voltage was set to 48V
- Controller pinout
J1 pin/color | Arduino pin | use |
13/brown | SCL_0 | |
15/red | SDA_0 | |
18/white | Alert#_0 | |
19/orange | \EN_B | |
21/blue | \EN_A | |
20/brown | ground | |
22/red | ground |