Version 3 (modified by 4 years ago) (diff) | ,
---|
- Status of all the boards, and qty working or expected to be working for each:
- 3 working LV Mixer RevA boards
- 3 working preamp RevA boards
- 1 working adapter board RevA board, 1 working adapter board RevB board, 1 should work after small surgery adapter board RevB
- 1 working HV RevA board, 1 working HV RevB board, 1 not working HV RevB board problem not identified
- 2 working filament supply RevB boards, 1 working filament supply RevA
- What work would need to be done in the EDF:
- Power supplies we expect our Chinese colleagues to provide:
+5V fixed supply up to X Amps for inside ToF box, -6V fixed supply up to X Amps for inside ToF box, adjustable up to ~2V supply up to X Amps for LV Mixer, and HV supply up to 200V. If the HV supply is adjustable and stable at 20V then no need for a LV supply, if not then an additional supply will be needed for the LV box adjustable up to 20V
- Cabling we expect our Chinese colleagues to provide:
DB9 cable connecting preamp to ToF box. DB15 cable connecting ToF box to LV or HV box. BNC connect
- Pricing for the enclosures (you did provide this for the FP express already):
Enclosure | Price($USD) |
LV | 135.54 |
HV | 135.87 |
preamp | 118.92 |
filament | 164.53 |
ToF | 127.97 + cuts |
Total | 682.83 + cuts |
- Rough estimate of additional work and cost to get from where we are to 4 sets of working electronics (installed + spare in China, ditto for here):