Version 13 (modified by 5 years ago) (diff) | ,
---|
Service Module Rev A ECOs (main board)
List:
- U15: ECO Link
- U23: ECO Link
- R94,R95,R96 Remove resistors.
- R50 should be 10k-ohms for CERN IPMC
- R52,R56,R61,R62 should be ~100-ohms
- Samtec headers for FP (J40, J46) are a bit too tall. Suggest sub SAM11085-ND (ESQ-106-23-L-D)
notes:
- 220uF caps should get smaller (physically, too tall)
- Remember to populate R50 with CERN IPMC value.
- We should add a pull-down to U15 pin 1 for when we have no IPMC (added on board 1)ECO Link
We should add a pull-up to ETH_SW_RESET_N(Has on-board pull-up, so we are OK)- Traces under mounting splice plate holes
- U23 has wrong DigiKey? part number ECO Link
- A pull up/down should be added between U24 pin 4 and U23 pin 7
Front panel board changes for Rev B
- Remove level shifter and wire direct uSD card to connector
- Change FT232RQ to FT232RL (TSSOP package)
- Wire
USB_UART_EN
toFT_3V3
through R2 instead of fromnDTR
- Change header P/N for headers for longer pins
Attachments (4)
-
APOLLO_RevA_ECO_U15.pdf (659.9 KB) - added by 5 years ago.
APOLLO RevA ECO for U15
-
APOLLO_RevA_ECO_U23.pdf (746.7 KB) - added by 5 years ago.
APOLLO RevA ECO for U23
-
R95-R92_4.7K_example.jpg (295.8 KB) - added by 5 years ago.
Example resistor placement for R95 to R92 4.7Kohm resistor
-
APOLLO_ESM_ECO.pdf (809.6 KB) - added by 5 years ago.
APOLLO RevA ECO for ESM