wiki:ServiceModuleRevAECOList

Version 10 (modified by Dan Gastler, 5 years ago) (diff)

--

Service Module Rev A ECOs (main board)

  • 220uF caps should get smaller (physically, too tall)
  • Remember to populate R50 with CERN IPMC value.
  • We should add a pull-down to U15 pin 1 for when we have no IPMC (added on board 1)ECO Link
  • We should add a pull-up to ETH_SW_RESET_N (Has on-board pull-up, so we are OK)
  • Traces under mounting splice plate holes
  • U23 has wrong DigiKey? part number ECO Link
  • A pull up/down should be added between U24 pin 4 and U23 pin 7

Front panel board changes for Rev B

  • Remove level shifter and wire direct uSD card to connector
  • Change FT232RQ to FT232RL (TSSOP package)
  • Wire USB_UART_EN to FT_3V3 through R2 instead of from nDTR
  • Change header P/N for headers for longer pins

Attachments (4)