Changes between Version 7 and Version 8 of HV_Pulser_Setup


Ignore:
Timestamp:
Aug 4, 2020, 3:49:37 PM (3 years ago)
Author:
Michael
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • HV_Pulser_Setup

    v7 v8  
    1111
    1212== Current Supply ==
    13 [[BR]]The HV Pulser has a current supply driven by the ON control signal. The purpose of this current supply is to offset the current drawn by the current sink discussed above. '''more details.''' The value of this supply current (in amps) can be described by the equation below.
    14 [[BR]]Isupply = 1.5V / R14Ohms
     13[[BR]]The HV Pulser has a current supply driven by the ON control signal. The purpose of this current supply is to offset the current drawn by the current sink discussed above. The value of this supply current (in amps) can be described by the equation below.
     14[[BR]]Isupply = 1.5V / (resistance of R14 in Ohms)
    1515
    1616== Control ==