* [http://ohm.bu.edu/~hazen/DataSheets/GE_Power/CP3500AC54TE_DS_July_22_2016.pdf Power Module] (model CP3000AC54TEZ) * [http://www.mouser.com/ds/2/167/CPB-CPL%203-17-16-473069.pdf Power Shelf] (we have a J2014003L001) ---- == Log == === 2016-09-12 Dan === config file updates for sane fan trays /etc/rc.comtel {{{ #CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned) CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned) }}} /etc/shelfman.conf.comtel {{{ #MIN_FAN_LEVEL = 40 MIN_FAN_LEVEL = 1 }}} /etc/shelfman.conf {{{ # COOLING_FAN_DECREASE_TIMEOUT = 0 COOLING_FAN_DECREASE_TIMEOUT = 1 # COOLING_FAN_INCREASE_TIMEOUT = 0 COOLING_FAN_INCREASE_TIMEOUT = 1 }}} === 2016-09-12 === * Using a POT, the power shelf output voltage was set to 48V * Controller pinout || J1 pin/color || Arduino pin || use || || 13/brown || || SCL_0 || || 15/red || || SDA_0 || || 18/white || || Alert#_0 || || 19/orange || || \EN_B || || 21/blue || || \EN_A || || 20/brown || || ground || || 22/red || || ground ||