* [http://ohm.bu.edu/~hazen/DataSheets/GE_Power/CP3500AC54TE_DS_July_22_2016.pdf Power Module] (model CP3000AC54TEZ) * [http://www.mouser.com/ds/2/167/CPB-CPL%203-17-16-473069.pdf Power Shelf] (we have a J2014003L001) * [https://www.artesyn.com/computing/products/product/atca-f140-40g-advancedtca-switch-blade ATCA-F140 Switch] ---- == IMPORTANT NOTES == * The COB's insertion lever's sensor is broken and you must run clia commands to install/uninstall it. This involves commands typed into the shelf manager (talk to Dan) To install: Insert COB as you normally would and then run the following command to tell the shelf the lever is correctly set {{{ clia sendcmd 0x96 0x2e 0x08 0x0a 0x40 0x00 0x00 0x01 }}} Where 0x96 is the IPMI address for the physical slot 2 and logical slot 11 To remove: Type the following command to simulate the lever being opened {{{ clia sendcmd 0x96 0x2e 0x08 0x0a 0x40 0x00 0x00 0x01 }}} Wait for the COB state to be inactive and then remove it physically. ---- == Log == === 2016-09-12 Dan === config file updates for sane fan trays /etc/rc.comtel {{{ #CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned) CARRIER_OPTIONS="USE_DEFAULT_COOLING=TRUE" # enables default cooling strategy (non-zoned) }}} /etc/shelfman.conf.comtel {{{ #MIN_FAN_LEVEL = 40 MIN_FAN_LEVEL = 1 }}} /etc/shelfman.conf {{{ # COOLING_FAN_DECREASE_TIMEOUT = 0 COOLING_FAN_DECREASE_TIMEOUT = 1 # COOLING_FAN_INCREASE_TIMEOUT = 0 COOLING_FAN_INCREASE_TIMEOUT = 1 }}} {{{ #COOLING_POLL_TIMEOUT =30 COOLING_POLL_TIMEOUT =5 }}} === 2016-09-12 === * Using a POT, the power shelf output voltage was set to 48V * Controller pinout || J1 pin/color || Arduino pin || use || || 13/brown || || SCL_0 || || 15/red || || SDA_0 || || 18/white || || Alert#_0 || || 19/orange || || \EN_B || || 21/blue || || \EN_A || || 20/brown || || ground || || 22/red || || ground ||