Carrier blade specs
This is a working page on keeping track of requirements for the BU ATLAS/CMS Carrier blade.
Expect this to change often.
Zone 2
Zone 1 / Power
Zynq
- ZYNQ DBS - Zynq daughterboard information
IPMC
Mezz
- Below is for each of two mezz boards
- So 2x the below for the double-width CMS mezz
Power/LS connector
- ET60T–D02–3–08–000–S–R1–S
- 2 power blades (12V + return) @ 60A max
- ~200 W per connetor
pos | Row 1 | Row 2 | Row 3
|
1 | +3.3V (uC) | +3.3V ret | en
|
2 | TMS | gnd | TCK
|
3 | TDO | gnd | TDI
|
4 | SDA sense IPMC | gnd | SCL sense IMPC
|
5 | TX IPMC | gnd | Rx IPMC
|
6 | TX ZYNQ | gnd | Rx ZYNQ
|
7 | ZYNQ GPIO1 | gnd | ZYNQ GPIO2
|
8 | ZYNQ GPIO3 | gnd | ZYNQ GPIO4
|
High-speed connector
- ERF8-RA
- 2.2A per pin (2-powered)
- pinout
1 | gnd | gnd
|
2 | Tx1-P | Tx2-P
|
3 | Tx1-N | Tx2-N
|
4-7 | gnd | gnd
|
8 | Rx1-P | Rx2-P
|
9 | Rx1-N | Rx2-N
|
10 | gnd | gnd
|
Mechanics
carrier buses
Ethernet
Port | type | use
|
| QSGMII | zynq fabric
|
| SGMII | zynq arm
|
| 10/100 | IPMC
|
| 10/100/1G | SERVICES 1
|
| 10/100/1G | SERVICES 2
|
| 10/100/1G | Front Panel
|
Serial number
Power supplies
- 12V (current: mezz?)
- 3.3V (current: ESC + IPMC?)
- 5V (Zynq supply?)
- 1.2V (CMS timing retimers)
- 2.5V (CMS XP switch)