Version 102 (modified by 4 years ago) (diff) | ,
---|
Service Module
Rev A
ID | Location | | Remote Access? | CM? | Cirex | Notes | ECOs | |
001 | BU (assembly room) | no | K | 98716 | Hard-wired 12V on, misc on, zynq bank IO on. Pulldown on zynq_en. 1k pulldown on U15 pin 1. Jumper on switch en to 3.3V. Removed R35 and R40. Test paused after zynq booted successfully. | 1, 2 | |
002 | BU (in Shelf for now) | no | - | 98724 | for show. Test paused after zynq booted successfully. Test completed. | 1, 2 | |
003 | BU (assembly room) | no | - | 1k pulldown on U15. switch fix. J28 has a connector, should be removed. LEDs lit up incorrectly, same as SM004. Stopped testing. | 1, 2 | ||
004 | BU (table) | no | - | 98719 | Resistor between R95 and R92 came off before step "put in zynq." LEDs lit up incorrectly. Stopped testing. Trial 2: Numerous LEDs lit up incorrectly at the same step (6: put in zynq). Stopped again. | 1, 2 | |
005 | Cornell | no | - | 98720 | LEDs hot-wired permanently on. Test completed. | 1, 2 | |
006 | BU | yes | K+V | 98721 | Test paused after zynq booted successfully. Test completed. | 1, 2 | |
007 | Amherst | - | - | 98723 | Missing LED after all ECOs completed. Resoldered new LED. Test completed. | 1, 2 | |
008 | CERN TIF | no | - | 98717 | Missing LED after all ECOs completed. Resoldered new LED. Test paused after zynq booted successfully. Test completed. | 1, 2 | |
009 | Cornell | - | - | 98725 | Test paused after zynq booted successfully. Test completed. | 1, 2 | |
010 | CERN TIF | - | ? | 98718 | Test paused after zynq booted successfully. Test completed. | 1, 2 | 19100056 |
ECO_1: Connect J5 pin-14 to 3V3_STBY through any lower 3 pins of J5 (p 2,4,6).
ECO_2: Add a 1k-Ohm resistor between the pad of R40 to GND pin of J12.
IPMC
Default IP is 192.168.1.34
CERN
ID | Location | MAC | IP | History |
19100056 | Cornell SM-05 | 00:50:51:FF:00:05 | -DHCP- (@BU 192.168.20.5) | |
19100057 | BU (Shelf) SM-06 | 00:50:51:FF:00:06 | -DHCP- (@BU 192.168.20.6) | |
19100059 | BU (table) | 00:50:51:FF:00:70 | 192.168.20.70 | Second special IPMC |
19100060 | CERN | 00:50:51:FF:00:08 | -DHCP- | In SM#8 at CERN |
19100062 | Cornell | 00:50:51:FF:00:09 | 192.168.20.62 | Assigned to SM009 not installed |
19100063 | Cornell | 00:50:51:FF:00:0A | 192.168.20.63 | Assigned to SM010 not installed |
19100067 | BU (shelf) SM-02 | 00:50:51:FF:00:02 | 192.168.20.67 | Final IPMC in SM002. |
19100069 | Amherst | 00:50:51:FF:00:07 | 192.168.20.69 | Final IPMC in SM007 |
19100070 | Cornell | 00:50:51:FF:00:70 | 192.168.20.70 | Special IPMC (1 of 3 at Cornell I believe -Felex) |
19100072 | BU (table) | 192.168.20.72 | Put in SM003 |
Switch
ID | Location | History |
21 | BU (Assembly Shelf) | Final in SM009 |
22 | BU (Assembly Shelf) | SM001 |
23 | BU (Assembly Shelf) | |
24 | BU (Assembly Shelf) | Used for special IPMC testing. Final switch in SM 007 |
25 | BU (Assembly Shelf) | Final in SM006 |
26 | BU (Assembly Shelf) | Final in SM008 |
27 | BU (Assembly Shelf) | Assigned to SM004 not installed |
28 | BU (Assembly Shelf) | Final in SM010 |
29 | BU (Assembly Shelf) | Final in SM002 |
30 | BU (Assembly Shelf) | This is the only one missing so I think SM005. |
31 | BU | SM-003 |
32 | BU (Assembly Shelf) | |
35 | BU (Assembly Shelf) | |
36 | BU (Assembly Shelf) | |
37 | BU (Assembly Shelf) | |
38 | BU (Assembly Shelf) | |
39 | BU (Assembly Shelf) | |
40 | BU (Assembly Shelf) | |
41 | BU (Assembly Shelf) | |
42 | BU (Assembly Shelf) |
FP Board
RevA
BU ID | FAB ID | Location | History |
0001 | BU (Bad pile) | ||
0002 | BU (Bad pile) | Had eco. | |
0003 | BU (Assembly Shelf) | ? | |
0004 | BU (Assembly Shelf) | ? | |
0005 | BU (Bad pile) | SM-001. Had eco. | |
0006 | BU (Assembly Shelf) |
Rev B
BU ID | FAB ID | Location | History |
0010 | Cornell ? | Using to test all blades up to after zynq boot. Previously zynq booted at varying rate. Final in SM009. | |
0011 | Amherst ? | LEDs did not light, replaced R1, fixed. Final in SM007. | |
0012 | BU (Bad pile) | SD Card Slot replaced. Weird behavior while testing SM007 after Zynq installed. | |
0013 | BU (table) | Blade 005. Table. | |
0014 | BU (Bad pile) | SD Card pins shorted | |
0015 | BU (table) |
Rev C
BU ID | FAB ID | Location | History |
20 | SM-10 | ||
- | 0001 | BU (table) | Button seems to stick. Seems good now. |
- | 0002 | BU (Shelf) | SM005 |
- | 0003 | BU (Bad pile) | |
- | 0004 | BU (table) | Zynq does not boot with this. |
- | 0005 | BU (Shelf) | SM006 |
- | 0006 | SM-08 ? | |
A | BU (Bad pile) | ? | |
B | BU (Bad pile) | red and green LEDs light up only once when usb plugged in (should be multiple times). Miniterm does not detect a usb connection. | |
C | BU (Bad pile) | red LED permanently on. | |
D | BU (Bad pile) | Zynq does not boot with this. ? Red and green LEDs do not come on and raspberry pi terminal freezes when plugged in. | |
E | BU (Bad pile) | ? | |
- |
Enclustra
ID | Type | location | eth0 mac | eth1 mac | history |
SN134522 | 35 | BU (table) | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | was in eval board (in SM001) |
SN141687 | 35 | Amherst? | 00-50-51-FF-20-07 | 00-50-51-FF-10-07 | Final in SM007 |
SN141688 | 35 | ? | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | |
SN144976 | 35 | Cornell? | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Final in SM009 |
SN144977 | 35 | Cornell? | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Final in SM010 |
SN144978 | 35 | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Test Zynq (6, 8, 2). Assigned to SM006 | |
SN144979 | 35 | BU (Assembly room) | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Assigned to SM004. Test Zynq (3, 1). |
SN144981 | 35 | BU (Assembly Shelf) | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | was in SM-001, dead in eval board.... |
SN141805 | 45 | BU (Shelf) | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Final in SM002 |
SN144930 | 45 | BU (Assembly Shelf) | 00-50-51-FF-2X-XX | 00-50-51-FF-1X-XX | Was in Dan's SM-001. |
MAC/IP address assignment
We use the lower bits to enumerate the Service Modules. The 2 upper bits would describe its IPMC and Zynq ports. This way, looking at the address, we know exactly which board we are talking about.
Another slight change would be to have the other 2 bits of the upper reserved digit as zeros, so it is easier to identify where our address region starts.
Instead of 4k, we would use 16K, like the following:
00-50-51-FF-00-00 to 00-50-51-FF-3F-FF
Or, in more detailes:
00-50-51-FF-YX-XX
XXX: Number of the Service module Y: IPMC or Zynq ports (00, 01, 10, 11)
For example:
IPMC of the SM1: 00-50-51-FF-00-01 ZYNQ port facing Eth sw of the SM1: 00-50-51-FF-10-01
IPMC of the SM2: 00-50-51-FF-00-02 ZYNQ port facing Eth sw of the SM2: 00-50-51-FF-10-02
IPMC of the SM15: 00-50-51-FF-00-0F ZYNQ port facing Eth sw of the SM15: 00-50-51-FF-10-0F
CMS Command Module
Rev A
# | Location | FPGAs | SM | notes |
1 | PSB | VU7P | - | for TIF |
2 | BU | KU15P | - | ATLAS? SM? |
3 | PSB | VU7P & KU15P | - | |
4 | PSB | VU7P & KU15P | - | |
5 | BU | VU7P & KU15P | SM-06 | |
6 | W231 | KU15P | - | |
7 | CERN TIF | VU7P & KU15P | SM-10 | |
8 | W231 | VU7P & KU15P | - | |
9 | W231 | VU7P & KU15P | - | |
10 | W231 | KU15P | - |