Board Location Voltages Blinky Current Firmware Load ADC test I/O Test Notes
01 BU all good 0.40A
02 BU all good 0.40A Blink code loaded OK
03 BU all good 0.40A Blink code loaded OK Cap C39 placed backwards and was replaced
tested after C39 was replaced
04 BU (Dan) all good 0.40A current 2018-06-13
05 BU all good 0.40A Blink code loaded OK
06 BU (Dan) all good 0.40A current 2018-06-13
07 BU (Dan) all good 0.40A current 2018-06-13
08* BU (Dan) all good 0.40A current 2018-06-13
09 BU (Second) all good 0.40A current 2018-06-13
10 BU all good 0.40A Blink code loaded OK

Boards assembly notes

ADC Board DC/DC converterProtection board Carrier boarddaughter boardFMC interfaceLocation comments
01 spare
02 009 004 Fermi
03 spare
04 010 005 01 01 001 BU
05 008 002 Fermi
06 004 008 01 01 001 BU
07 005 007 01 01 001 BU
08 002 006 01 01 001 BU
09 007 003 Fermi
10 006 001 Fermi

The whole setup with 4 ADC boards uses approximately 3.6A max.